VOLTA FST EMAT System | Boiler Tube Inspection & Non-Contact Ultrasonic Testing
VOLTA FST is a portable EMAT (Electromagnetic Acoustic Transducer) ultrasonic testing system specifically designed for boiler tubes and thin-wall structures. Its non-contact inspection capability eliminates the need for couplant, enabling fast, reliable thickness measurement and flaw detection even on rough or oxidized surfaces. It is optimized for field use, significantly improving inspection speed and maintenance efficiency.
Online Catalog ↗ Not sure this is the right one? Find it in 3 questions →VOLTA FST is a compact and portable ultrasonic testing system based on EMAT technology, designed for the inspection of boiler tubes, pipelines, and pressure vessels. By enabling true non-contact measurements, the system eliminates the need for surface preparation, ensuring consistent and reliable results even on coated, oxidized, or high-temperature surfaces.
The system is available in two main configurations:
- VOLTA FST-B: A single-channel unit with an integrated magnet pulser, ideal for manual inspection of boiler tubes
- VOLTA FST-32: An advanced version with an 8:32 multiplexer, designed for automated inspections using scanning systems
VOLTA FST is particularly optimized for detecting hydrogen-induced cracking (HIC/HCC) and performing accurate wall thickness measurements in boiler tubes. Combined with handheld scanners, it enables fast and efficient field inspections, making it an ideal solution for maintenance and shutdown operations.
The system is also widely used for inspection of pipelines, pressure vessels, and industrial plant components. Its EMAT-based non-contact technology ensures reliable performance with minimal influence from surface conditions such as paint, scale, or roughness.
Applications:
VOLTA FST is designed for EMAT-based inspection applications in industries such as power generation, oil & gas, petrochemical plants, and heavy industry.
-
Boiler Tube Inspection
Thickness measurement and detection of hydrogen-induced cracking (HIC/HCC) in boiler tubes -
Pipelines & Pressure Vessels
Non-contact ultrasonic inspection of pipelines and pressure equipment -
Maintenance & Shutdown (MRO) Applications
Fast scanning and defect detection during maintenance operations -
High-Temperature & Harsh Surfaces
Reliable inspection on oxidized, coated, or rough surfaces without surface preparation
Key Specifications:
- Channels: 1 (FST-B) / 8:32 multiplexer (FST-32)
- Frequency range: 1 – 5 MHz
- Inspection modes: Pulse-Echo / Pitch-Catch
- Pulse repetition rate: up to 60 Hz
- Gain: 20 – 100 dB
- ADC: 14-bit, 125 MSps
- Digital filtering: FIR filters
- Encoder: A/B quadrature support
- Connectivity: Wi-Fi, Bluetooth 5.0, USB 3.0, Ethernet
- Software: ITOP + NDT-WEB
- Storage: up to 500 GB SSD
- RAM: 8 GB
- Battery: 4–8 hours (hot-swappable)
- Weight: approx. 9 kg
Which equipment is right for you?Pick what you need to do:
Find surface cracks / surface defectsFind internal defects (voids, inclusions, weld flaws)Measure wall thickness or corrosionMeasure hardnessIdentify or sort materials (alloy, hardness)See or measure inside pipes, engines, turbinesInspect steel wire ropesClean parts (ultrasonic cleaning)Find calibration or reference blocks
Start the Product Finder →CONTACT
Tell us about your inspection needs — we will choose the right solution together.
Cumhuriyet Mah. Demokrasi Cad. No: 60/B
Çekmeköy / İstanbul +90 216 235 15 31 info@nexsen.com.tr Message us on WhatsApp →